SURFACE CONTROLLED SUBSURFACE SAFETY VALVES (SSSV)
Actinc usa
2018-12-03T08:25:00+00:00
SURFACE CONTROLLED SUBSURFACE SAFETY VALVES (SSSV)
ACT model safety valves are installed in the upper wellbore to provide emergency closure of the producing conduits in the event of an emergency. The safety valve system is designed to be fail safe, so that the wellbore is isolated in the event of any system failure or damage to the surface production control facilities. ACT model safety valve is self equalizing, wireline retrievable, suface controlled and flapper type. ACT model Safety Valves are installed in ACT model Landing Nipples.
FEATURES:
-
Self equalizing type
-
Working pressure up to 10,000 psi
-
Sealing and sealing surfaces are out of flow path, when valve is in the open position
-
Solid construction of flapper made from bar stock
FLAPPER-TYPE WIRELINE-RETRIEVABLE SAFETY VALVES |
Tubing Size |
Landing Nipple Seal bore |
Valve ID |
* Working Pressure |
in. |
mm. |
in. |
mm. |
in. |
mm. |
psi |
2.3/8 |
60.33 |
1.710 |
43.43 |
0.62 |
15.75 |
5,000
6,000
7,500
10,000 |
1.875 |
47.63 |
0.75 |
19.05 |
2.7/8 |
73.03 |
2.125 |
53.98 |
0.81 |
20.57 |
2.188 |
55.58 |
0.81 |
20.57 |
2.313 |
58.75 |
1.12 |
28.45 |
3.1/2 |
88.90 |
2.562 |
65.07 |
1.00 |
25.40 |
2.750 |
69.85 |
1.50 |
38.10 |
2.813 |
71.45 |
1.50 |
38.10 |
4 |
101.60 |
3.313 |
84.15 |
1.75 |
44.45 |
4.1/2 |
114.30 |
3.437 |
87.30 |
1.75 |
44.45 |
3.688 |
93.68 |
1.87 |
47.50 |
3.813 |
96.85 |
2.12 |
53.85 |
5 |
127.00 |
4.125 |
104.78 |
2.38 |
57.15 |
5.1/2 |
139.70 |
4.562 |
115.87 |
2.56 |
65.02 |
7 |
177.80 |
5.750 |
146.05 |
3.38 |
85.85 |
5.875 |
149.23 |
3.50 |
88.90 |
5.963 |
151.46 |
3.50 |
88.90 |
* Please check with factory for the metallurgy & pressure rating